Home Page
Quality Control
Certification And Brochures
Career
Business Opportunities
Export Enquiry
Image Gallery
Contact Us
Fetal Doppler
DS120A Fetal Doppler
Safetly :
The whole process of design, material purchase and production in compliance with CE standard.
Precise :
Special HR self correlation reading algorithm and continuous working method to ensure and reliable fetal heart rate (FHR) measurement
Artistic Outlook :
Compctness, setreamline and portable design
Durability:
Qualified material, presciseness production process and experienced workers with ISO13485 quality management system secure the long life usage of product
Features:
LCD display with backlight, can be used in any illumination conditions
Accurate and reliable FHR Detection with clear sound.
High sensitivity probe with 2.0MHZ in continuous wave
Ergonomic design, portable and convient.
Built in  speaker.
Automatically poweroff.
Multi-displaying of FHR: number, battery status indicator, Voice intensity indicator.
Building-in rechargeable battery and AC recharger.
Dimension:
Dimesion: 330x230x70mm
G. weight:<1.0 KGS
Power Supply:
Power: Built-in Chargeable Battery, DC, 7.4 V
Li-ion battery
AC recharger
Working Environment:
Temperature: +5c 40c
Humadity: <85%
Transportation and storage Environment:
Temperature: +10'C-+ 55'C
Humadity: <90%
 
Technical Specification:
LCD Display Dimension:
39 x27 mm
Speaker power: 1 W
Power Supply:
Built-in Rechargeable battery;
Working Voltage: 7.4V
Continuous operating time:> 5 hours.
AC recharger.
Ultra Sound:
Frequency: 2.0 MHz continual wave
intensity: <2mW/cm of 2.0 MHz
P: <0.35MPa
FHR:
Display: LCD display
Measurement Range: 50- 210 BPM (Option: 30-240BPM of 2.0 MHZ)
Mesurement Accuracy: 1% or 1 BPM
 
Fetal Monitor:
Features:
10.2” inch large-screen color TFT display, digital display and waveform oscilloscope of twins heart rate (FHR) and uterine contraction pressure (TOCO) value.
Indepedent User friendly interface with function setting. Unique rotary buttom control design, portable and convient.
Self-defination of multi-event marks.
Directly viewing 1;1 scale of display and print-out waveform.
Folding thermal array printer with high resolution, easy paper loading, paper empty auto detection and printing head over-heating protection.
7-wafer impulse ultrasound transduser, configured with special hr self Correlation reading algorithm to ensure correct and reliable fetal heart rate (FHR) measurement.
highly sensitive, wide scope pressure transducer ensures to achieve effective measurement of uterine contraction pressure (TOCO).
Fetal movement auto detection.
Signal intensity indication ensures effective tranducer position.
Auto power failure protection and reliable rechargeable li-ion battery and realize continual monitoring functio
Net-working capacity, convient and ease-of-use. Convient for hospital information management and for data analysis of fetal central monitor system.
Meets the standard IEC60601-1, 1988, class I, type B with special protection from electroshock, safe and reliable in use
Fetal heart rate (FHR) measurement:
Measuring method: Ultrasound doppler
Measuring scope : 50-240BPM
Measuring tolerance : less than +_ 1BPM
Fetal heart rate curve scope: 50-240BPM
Fetal heart rate numeric display scope: 50-240BPM
Ultrasound working frequency : 2MHz, 2.5MHz
Ultrasound output intensity: <5mW/cm2
Uterine contraction pressure (TOCO) measurement
Measuring method: External measuring
Measuring scope : 0-100 unit
Uterine contraction pressure curve scope : 0-100 unit
Uterine contraction pressure numeric display scope: 0-100 unit
Non-linearity tolerance ; less than +_ 10%
Auto-zero function : yes
Fetal movement record :
manual control button label, Auto fetal movement identification
Display : 10.2" color TFT-LCd(800RGBx480)
Event mark : 9 available
Record Mode : Thermal array printer
Record paper: 112mmx100mm folded thermal printing paper
Paper feeding speed : low limit 120 bpm, up limit 160 BPM
Fetal heart rate audible and visual alarm: low limit 120 bpm, up limit 160 BPM
Alarm trigger time : <3s
Printer failure alarm : paper empty alarm
Output volume : 2-3w speaker, volume adjustable
Power supply :
AC: 100-240v, %0/60hz+_ 1hz, 40VA
DC:14.4V/2000mAh, rechargeable LI-ion battery, continuous work>4h
safety level ; Class 1, type B
Size : l296 mmX w312mmXH92 mm
net-working capacity :
Yes
 
Fetal and maternal Monitor:
Features:
9 Standards parameters:ECG,RESP,NIBP,SPO2,1-TEMP, PR/HR, FHR TOCo, FM
12.1 “ high resolution color TFT LCD display. simple and friendly operating display interface
9-wafer impulse ultrasound transducer, configured with special HR self correlation reading algorithm to ensure correct and reliable fetal heart rate(FHR) measurement.
Large built-in chargeable battery provides convience for patient moving
play back and browse function for history waveform and monitor data record.
Optional printing output function, alarm triggers printing.
Auto double alarm with Audible and visible signals
Anti-defibrillation, anti-interferance from high frequency electric knife
Pace-maker detection.
A full-synchronistic leads, multi-channel ECG display
Indication of incorrect manipulation and malfunction analysi
Unique accessory management cabinet.
Safety:
IEC60601-1 approved, Category IBF, CF Type
Dimension and weight;
300mm X 400mm X 500mm
G. Weight: <9.0KGS
Operation Environment;
Temperature: working 5-40'C
Humidity: working <85%
Power: AC 100-240V, 50/60 Hz
Patient Range;
adult, pediatric, neonate, and fetus
Optional:
Thermal recorder.
Specification:
Display:12.1" color TFT, Rolloing and refreshing waveform display,
Resolution: 800X600
Trace:4 waveform,
sweep speed: 12.5mm/s,25mm/s, 50mm/s
Indicator: power/battery indicator light, QRS beep and alarm sound
Battery: Rechargeable built-in battery, above 2 hours for continuous working.
Trend tim: 72 hours
Alarm: User-adjustable High, Medium and low limits, 3-level Audible and visual alarm
Recorder: Built-in, thermal array Plethymogram waveform:1 channels, record mode: manual, on alarm, time defined, Recording width: 50mm, Printing speed; 25mm/s.
ECG:
Lead mode:5-lead,RA, LA, RL, LL, V
Lead section: I,II,III,avR,V,MCL
sweep speed:12.5mm/s,25mm/s, 50mm/s
Heart Rate Range: 15-300bpm
Accuracy: +_1bpm or +_1%, whichever is greater
Resolution: 1bpm
Filter:surgery mode:1-25Hz, Monitor mode: 0.5-35Hz, Diagnostic mode: 0.05-100Hz
Scalling Signal:1mV,+_3%
Alarm Range: 20-250bpm
S-T segnent detection:Measurement range:-2.0mV- +2.0 mV, Alarm Range:-2.0mV- +2.0 mV,
NIBP:
Operation mode: Manual/Automatic
Auto measurement time:Adjustable(1-120min)
Measurement Unit:mmHg/Kpa selectable
Measurement Types: Systolic, Diastolic, Mean
Measurement range:Systolicc,diastolic,Mean
Over-pressure protection: Double safety protection
SPO2:
Measurement range: 0-100%
Resolution :1%.
Accuracy : 2%(80-100%); 1-69% unspecified
Alarm range : 1-100%
RESPIRATION :
Method: Thoracic impedance
Measurement Range:1-99rpm
Alarm range: 1-99 rpm
Resolution: 1 rpm
Accuracy : 2rpm
TEMPERATURE :
Measurement Range:25-45 c
Resolution:  0.1 c
Accuracy: 0.1 c
Channel: 1l-channel,
PR :
Measurement Range:15-300bpm
Resolution: 1bpm
Accuracy: 1bpm
Alarm range:15-300bpm
TOCO:
Measurement Range:0-100 unit
NON-linearity tolerance:8%
Accuracy: 1unit
Auto-zero function: yes
FHR:
Measurement Range:60-210BPM
Accuracy: 2rpm
Resolution: 1rpm
Transducer: Ultrasound output intensity:<3mW/cm2, Ultrasound working frequency: 1.0 MHz
Fetal movement record
manual control button label, Auto fetal movement identification
 
Home About Us Products Research & Development Quality Control Certification Brochures Career Export Enquiry Image Gallery Contact Us
Copyright © Cosmos Advanced Diagnostics LLP.